Transonic Systems, Inc.

ITHACA, NY 14850

SBIR Award Summary

Total Number of Awards 34
Total Value of Awards $9.26MM
First Award Date 09/30/87
Most Recent Award Date 07/01/17

Key Personnel

Last Name Name Awards Contact
Drost Cornelis Johannes Drost 8
Krivitski Nikolai M Krivitski 23
Milanowski G J Milanowski 3

34 Awards Won

Phase 2 SBIR

Agency: Department of Health & Human Services
Topic: PA-16-302
Budget: 07/01/17 - 04/30/18

7. PROJECT SUMMARY/ABSTRACT Venoarterial Extracorporeal Membrane Oxygenation (VA ECMO) is a way to provide cardiac and pulmonary support to patients without other alternatives. This form of life support is vital to pediatric and neonatal patients. As with any life support, there are serious complications that occur. These complications including...

Phase 1 SBIR

Agency: Department of Health & Human Services
Topic: RFA-HD-10-012
Budget: 08/01/12 - 07/31/13

DESCRIPTION (provided by applicant): There is no current technology for routine measurement of shunt flow (Qp:Qs - ratio of pulmonary to systemic blood flow) in newborns and small children in the intensive care unit (ICU). Current methods either require placement of highly invasive catheter or depend on assumptions, leading to risky and less acc...

Phase 1 SBIR

Agency: Department of Health & Human Services
Topic: RFA-HD-10-012
Budget: 08/23/11 - 07/31/12

DESCRIPTION (provided by applicant): There is no current technology for routine measurement of shunt flow (Qp:Qs - ratio of pulmonary to systemic blood flow) in newborns and small children in the intensive care unit (ICU). Current methods either require placement of highly invasive catheter or depend on assumptions, leading to risky and less acc...

Phase 2 SBIR

Agency: Department of Health & Human Services
Topic: PA-07-280
Budget: 06/01/11 - 05/31/13

DESCRIPTION (provided by applicant): Currently there exists no technology for routine measurement of cardiac output (CO) in neonates (0.4-2.5Kg) and low weight pediatric (2.5Kg+) patients in the intensive care unit (ICU). Accurate measurement of CO would allow for better assessment of therapies and thereby improve patient health care. Convention...

Phase 1 SBIR

Agency: Department of Health & Human Services
Topic: PA-09-080
Budget: 09/15/10 - 05/31/13

DESCRIPTION (provided by applicant): More than 64,000 US pediatric patients/year are diagnosed with ARDS (Acute Respiratory Distress Syndrome) - a life-threatening lung dysfunction in many cases related to lung edema, with a 30-40% fatality rate. The onset, progression, and treatment of ARDS can be monitored by measuring patient Extra-Vascular L...

Phase 2 SBIR

Agency: Department of Health & Human Services
Topic: PA-07-280
Budget: 07/01/10 - 06/30/13

DESCRIPTION (provided by applicant): Nearly 30,000 neonatal and pediatric children worldwide undergo Extracorporeal Life Support (ECLS) each year. Unfortunately, their doctors currently cannot objectively determine when a child's heart and lungs are strong enough to safely wean from life support. Transonic proposes to meet this need by developin...

Phase 2 SBIR

Agency: Department of Health & Human Services
Topic: PA-07-280
Budget: 06/01/09 - 05/31/11

DESCRIPTION (provided by applicant): Currently there exists no technology for routine measurement of cardiac output (CO) in neonates (0.4-2.5Kg) and low weight pediatric (2.5Kg+) patients in the intensive care unit (ICU). Accurate measurement of CO would allow for better assessment of therapies and thereby improve patient health care. Convention...

Phase 2 SBIR

Agency: Department of Health & Human Services
Topic: PA-07-80
Budget: 09/19/08 - 05/31/09

DESCRIPTION (provided by applicant): Currently there exists no technology for routine measurement of cardiac output (CO) in neonates (0.4-2.5Kg) and low weight pediatric (2.5Kg+) patients in the intensive care unit (ICU). Accurate measurement of CO would allow for better assessment of therapies and thereby improve patient health care. Convention...

Phase 2 SBIR

Agency: Department of Health & Human Services
Topic: PA-07-80
Budget: 09/15/08 - 06/30/10

DESCRIPTION (provided by applicant): Nearly 30,000 neonatal and pediatric children worldwide undergo Extracorporeal Life Support (ECLS) each year. Unfortunately, their doctors currently cannot objectively determine when a child's heart and lungs are strong enough to safely wean from life support. Transonic proposes to meet this need by developin...

Phase 2 SBIR

Agency: Department of Health & Human Services
Topic: PA-06-20
Budget: 06/01/08 - 05/31/10

DESCRIPTION (provided by applicant): Hydrocephalic shunt dysfunction diagnosis is one of the most complicated and time consuming aspects of treating hydrocephalic infants and young children, since preverbal children cannot describe such critical symptoms as persistent headaches. One must instead rely on observable symptoms that often resemble th...

Load More